Precision You Can Trust
NABL-Accredited Calibration | Available on Request
The Pico PT100 General-Purpose Probe is a Class A platinum resistance thermometer designed for accurate temperature measurement in immersion, air and insertion applications. It offers a −30 °C to +350 °C temperature range, ±0.15 °C accuracy at 0 °C, a 150 mm × 6 mm stainless-steel probe, 2 m PVC cable, four-wire construction and a 4-pin mini-DIN connector for compatible Pico temperature data-logging systems..
The Pico SE011 PT100 General-Purpose Probe, Class A, 2 m is designed for engineers, laboratories, research teams and industrial users who require reliable PT100 temperature measurement across a broad range of general-purpose applications.
Pico Technology specifies the SE011 as a general-purpose Class A platinum resistance thermometer probe suitable for non-specialized temperature measurements in:
The probe combines Class A PT100 measurement performance with a stainless-steel sensing body, four-wire connection and a 2 m cable for flexible installation.
The SE011 uses a PT100 platinum resistance thermometer with:
This makes it suitable for applications where reliable general-purpose temperature measurement is required without moving to a higher-cost 1/10 DIN precision sensor.
Typical applications include:
Pico specifies the operating temperature range as:
The +350 °C upper limit makes the SE011 suitable for higher-temperature general-purpose measurements compared with several lower-temperature PT100 probes in Pico's accessory range.
Applications may include:
The installation must remain appropriate for the probe materials and stated temperature range.
Pico specifically lists immersion as one of the intended measurement applications for the SE011.
The stainless-steel probe can therefore be used for suitable liquid-temperature measurements where:
The complete probe assembly should always be installed according to the requirements of the measurement environment.
The SE011 can also be used for general air-temperature measurements.
Typical uses include:
For air measurement, response time can depend on airflow, probe positioning and the thermal mass of the stainless-steel probe.
Pico also specifies the SE011 for insertion applications.
The 150 mm probe length provides useful reach for suitable measurement points in:
The SE011 should only be inserted into materials or locations that are suitable for its 6 mm stainless-steel probe construction.
The SE011 has a manufacturer-specified sensing probe size of:
The probe itself is manufactured from:
This provides a defined physical construction for general-purpose temperature measurements.
The probe includes a:
The 2 m lead provides flexibility where the temperature measurement point is located away from the data logger.
This can be useful for:
Cable routing should take account of the temperature and environmental conditions around the cable itself.
The SE011 uses a:
Four-wire measurement is particularly useful with resistance temperature detectors because a compatible measurement instrument can compensate for resistance introduced by the connecting leads.
This helps prevent lead resistance from being interpreted as additional PT100 sensor resistance.
The four-wire configuration is therefore well suited to precision PRT measurement instruments such as the Pico PT-104.
The SE011 is terminated with a:
This provides direct connection to compatible Pico PRT measurement equipment.
The connector should not be described as “Tenth DIN.” A DIN sensor accuracy classification and a mini-DIN electrical connector are completely different specifications.
For the SE011:
Pico Technology currently lists the SE011 as a recommended sensor for the PT-104 High-Accuracy Temperature Data Logger.
The PT-104 provides four PRT measurement channels and supports standard PT100 and PT1000 sensors.
Using SE011 probes with the PT-104 allows engineers to create systems for:
Multiple SE011 probes can be connected to available PT-104 input channels for simultaneous temperature monitoring.
The published ±0.15 °C at 0 °C value refers to the accuracy specification of the SE011 PT100 probe.
The accuracy of the complete measurement system also depends on:
For high-accuracy or traceable measurements, users should evaluate the complete probe-and-logger measurement chain.
Pico specifies:
The stainless-steel probe connects directly to the 2 m cable rather than using a separate handheld probe body.
This makes the SE011 suitable for:
The Pico SE011 is suitable for:
The SE011 provides:
This is the correct manufacturer specification for this probe.
The SE011 uses a PT100 platinum resistance sensing element.
PT100 sensors are commonly used for temperature measurement because their resistance changes in a defined relationship with temperature.
The manufacturer-specified range is:
The +350 °C maximum makes the SE011 suitable for a broader high-temperature range than Pico's SE012 1/10 DIN probe and SE019 low-cost Class A probe.
Pico specifically identifies the SE011 for:
This makes it a flexible general-purpose PT100 sensor for laboratory and engineering environments.
The probe uses:
This enables compatible measurement instruments to compensate for resistance in the probe leads and helps maintain accurate resistance-based temperature measurements.
The probe has a published length of:
This provides useful reach for immersion and insertion applications where the physical installation is suitable.
The stainless-steel probe has a diameter of:
This dimension should be considered when selecting holes, fittings, test fixtures or insertion points.
Pico specifies:
This is preferable to using generic marketing phrases such as “robust construction” because it provides users with the actual manufacturer-published material.
The SE011 includes a:
The extended cable length supports temperature measurements where the sensor needs to be positioned away from the logging instrument.
The manufacturer specifies:
Users should take the cable material into account when routing the lead near hot surfaces or other demanding environmental conditions.
The probe uses:
This provides direct connectivity to compatible Pico PT100 measurement equipment, including the PT-104.
Pico officially lists the SE011 as a recommended accessory for the PT-104 High-Accuracy Temperature Data Logger.
This provides manufacturer-confirmed compatibility for PT100 data-logging applications.
The SE011 is supplied:
Its probe-and-cable construction is appropriate for installed and general laboratory measurements rather than being specifically configured as a handheld probe.
| Feature | SE011 General Purpose | SE019 Low-Cost |
|---|---|---|
| Accuracy | ±0.15 °C at 0 °C | ±0.15 °C at 0 °C |
| Accuracy Class | Class A | Class A |
| Temperature Range | −30 °C to +350 °C | −75 °C to +260 °C |
| Probe Length | 150 mm | 120 mm |
| Probe Diameter | 6 mm | 3 mm |
| Cable Length | 2 m | 1 m coiled |
| Cable Material | PVC | PVC |
| Wiring | 4-wire | 4-wire |
| Connector | 4-pin mini-DIN | 4-pin mini-DIN |
| Handle | No | Yes |
| Primary Use | General-purpose immersion, air and insertion | Economical general-purpose measurements |
Choose the SE011 when a longer 2 m cable, 150 mm probe and higher +350 °C upper temperature limit are useful.
| Specification | Details |
| Manufacturer | Pico Technology |
| Model / Order Code | SE011 |
| Product Name | PT100 Probe, General Purpose, Class A, 2 m |
| Product Type | Platinum Resistance Thermometer / PT100 Probe |
| Sensor Type | PT100 |
| Accuracy Class | Class A |
| Accuracy at 0 °C | ±0.15 °C |
| Temperature Range | −30 °C to +350 °C |
| Recommended Measurement Types | Immersion, air and insertion |
| Probe Length | 150 mm |
| Probe Diameter | 6 mm |
| Cable Length | 2 m |
| Probe Material | Stainless steel |
| Cable Material | PVC |
| Connector | 4-pin mini-DIN |
| Number of Wires | 4 |
| Handle | No |
| PT-104 Compatibility | Recommended accessory |
| Primary Applications | General temperature logging, laboratory measurements, immersion, air and insertion testing |