Precision You Can Trust
NABL-Accredited Calibration | Available on Request
The Pico Technology TA346 is a premium manual SOLT calibration kit designed for accurate two-port vector network analyser calibration from 300 kHz to 8.5 GHz. It combines precision 50 Ω PC3.5 male short, open, load and through standards in a four-piece, five-port assembly. Serial-number-specific traceable calibration data, tight-tolerance stainless steel connectors and a protective carrying case support precision RF, microwave and network metrology applications..
The Premium 8.5 GHz SOLT Calibration Kit with PC3.5 Male Connectors, order code TA346, is designed for laboratories, production facilities, telecom development teams and research organisations that require dependable VNA calibration with low connector-related uncertainty.
The kit contains mechanical calibration standards that must be connected manually during the calibration sequence.
It includes:
Pico Technology supplies the standards as an assembled five-port SOLT unit. The assembly can be separated for individual use, inspection, cleaning or refurbishment if one standard becomes damaged.
SOLT calibration uses four known reference conditions:
These standards allow the vector network analyser to calculate correction terms for systematic measurement errors, including:
The TA346 is a manual calibration kit. Each standard is connected separately when requested by the VNA calibration software.
It should not be described as:
Pico separately offers the TA518, TA519 and TA520 electronic E-Cal products for automated calibration.
The TA346 uses precision PC3.5 male connectors.
PC3.5 is a precision 3.5 mm coaxial interface designed for repeatable RF and microwave measurements. It is mechanically compatible with properly specified SMA female connectors, while providing tighter manufacturing tolerances than standard-grade SMA calibration interfaces.
The male kit is suitable for measurement setups terminating in:
The corresponding premium female calibration kit is the TA347.
The TA346 is characterised across a frequency range of:
This supports calibration for measurements involving:
The complete range should be written as 300 kHz to 8.5 GHz, rather than only stating 8.5 GHz.
Pico describes the TA346 as a four-piece, five-port calibration kit.
The assembly contains:
Together, these provide five PC3.5 male connection ports.
The modular design allows the kit to be:
This construction helps extend the usable life of a premium calibration kit.
Each TA346 is supplied with traceable calibration data linked to the individual kit serial number.
The characterisation represents the measured frequency-dependent behaviour of the:
The VNA uses this information to correct for the non-ideal electrical behaviour of the standards.
Characterisation data helps account for:
Pico states that its manual kits are fully characterised and supplied with traceable calibration data rather than relying only on idealised standard models.
Pico Technology offers standard-grade and premium-grade manual SOLT kits.
| Feature | TA346 Premium Kit | TA344 Standard Kit |
|---|---|---|
| Connector type | PC3.5 male | SMA male |
| Calibration type | Manual SOLT | Manual SOLT |
| Frequency range | 300 kHz to 8.5 GHz | 300 kHz to 8.5 GHz |
| Construction | Four-piece, five-port | Four-piece, five-port |
| Characterisation | Serial-number-specific | Serial-number-specific |
| Typical use | Precision and reference calibration | General laboratory calibration |
The premium kit is appropriate where connector repeatability and measurement uncertainty are particularly important.
Common use cases include:
The TA346 load standard provides the following published return-loss performance:
| Frequency Range | Uncorrected Return Loss | Corrected Return Loss |
|---|---|---|
| Up to 3 GHz | ≥30 dB | ≥46 dB |
| Above 3 GHz to 8.5 GHz | ≥26 dB | ≥43 dB |
Corrected return loss applies when the supplied characterisation data is used during calibration.
A well-characterised load contributes to accurate correction of:
The open standard has the following published return-loss limits:
| Frequency Range | Return Loss |
|---|---|
| Up to 3 GHz | ≤0.15 dB |
| Above 3 GHz to 8.5 GHz | ≤0.20 dB |
The open standard is not treated as an ideal open circuit. Its actual frequency-dependent response is included in the supplied calibration data.
The short standard provides:
| Frequency Range | Return Loss |
|---|---|
| Up to 3 GHz | ≤0.20 dB |
| Above 3 GHz to 8.5 GHz | ≤0.25 dB |
The characterisation accounts for the actual delay, loss and inductive behaviour of the short standard.
The through adaptor provides:
The through adaptor is used to calculate forward and reverse transmission correction terms during two-port calibration.
Pico supplies the new TA346 with traceable calibration data linked to its serial number.
Traceable characterisation supports:
A separate NABL calibration certificate should only be mentioned where RevineTech has confirmed that it is supplied under its own calibration scope for this specific kit.
The official Pico listing confirms traceable data and a protective case, but does not identify an NABL certificate as a standard manufacturer inclusion.
A normal two-port SOLT procedure includes:
Correct handling remains essential because a precision calibration kit cannot compensate for dirty, damaged or incorrectly torqued connectors.
PC3.5 standards should be handled carefully to protect the centre conductor and reference plane.
Good practice includes:
Pico lists the TA356 dual-break torque wrench for SMA, PC3.5 and K-type connectors.
Correct torque supports:
A check standard may be measured after calibration to confirm that the complete measurement setup is working correctly.
Compatible Pico check standards include:
Verification can help identify:
The SOLT kit establishes the VNA error correction. A check standard independently verifies the calibrated measurement system.
Pico product code CC048 is the recalibration service for existing premium male or female SOLT kits.
The service applies to:
The existing kit must be returned to Pico after obtaining an RMA number. Updated calibration data is supplied on USB memory.
Recalibration may be considered when:
The TA346 can be used with:
The selected measurement range must remain within the kit’s 300 kHz to 8.5 GHz characterisation range.
The Pico TA346 is suitable for:
Includes mechanical:
Supports VNA calibration across RF, wireless and microwave applications.
Corrected return loss:
Supports secure storage and transport of the precision standards.
| Specification | Pico TA346 |
|---|---|
| Product name | Premium 8.5 GHz SOLT Calibration Kit, PC3.5 Male |
| Order code | TA346 |
| Pico type | SOLT-PREM-M |
| Product type | Premium manual mechanical VNA calibration kit |
| Calibration method | Two-port SOLT |
| Standards included | Short, open, load and through |
| Construction | Four-piece, five-port assembly |
| Connector type | PC3.5 male |
| Nominal impedance | 50 Ω |
| Characterised frequency range | 300 kHz to 8.5 GHz |
| Connector construction | Tight-tolerance stainless steel |
| Characterisation | Serial-number-specific traceable data |
| Electronic switching | No |
| USB interface | No |
| Internal temperature oven | No |
| Protective carrying case | Included |
| Parameter | Up to 3 GHz | Above 3 GHz to 8.5 GHz |
|---|---|---|
| Uncorrected return loss | ≥30 dB | ≥26 dB |
| Corrected return loss | ≥46 dB | ≥43 dB |
| Parameter | Up to 3 GHz | Above 3 GHz to 8.5 GHz |
|---|---|---|
| Return loss | ≤0.15 dB | ≤0.20 dB |
| Parameter | Up to 3 GHz | Above 3 GHz to 8.5 GHz |
|---|---|---|
| Return loss | ≤0.20 dB | ≤0.25 dB |
| Specification | Value |
|---|---|
| Maximum insertion loss | 0.20 dB |
| Characterised frequency range | Up to 8.5 GHz |
| Connector type | PC3.5 male |
| Nominal impedance | 50 Ω |
| Serial-number-specific data | Included |
| Specification | Details |
|---|---|
| Data type | Full S-parameter characterisation |
| Frequency range | 300 kHz to 8.5 GHz |
| Kit identification | Linked to the individual serial number |
| Traceability | Traceable calibration data |
| New-kit data | Included |
| Recalibration service | CC048 |
| Recalibration delivery | Updated data supplied on USB memory |