The TA313 is a passive 3 GHz, 50 Ω SMA female to BNC male inter-series adaptor for connecting SMA male RF accessories to BNC female oscilloscope and test-equipment inputs. Its compact straight-through configuration is particularly useful with Pico low-impedance probes and compatible PicoScope oscilloscopes, providing a convenient interface between SMA and BNC connections in RF, pulse, electronics and laboratory measurement setups..
The Network Metrology Premium PC3.5(f) Demonstrator Kit, product code PQ188, is designed for RF engineers, universities, research laboratories, postgraduate training, production facilities and measurement teams that need a complete set of premium accessories for accurate vector network analyser calibration and measurement verification.
The kit combines:
The PQ188 package can be used to realise and verify the measurement capability of a PicoVNA. It also helps users demonstrate how calibration-kit quality, connector condition, cable movement, measurement uncertainty and reference standards affect VNA results.
The official PQ188 package contains:
The current RevineTech page should add the TA431 check standard, as it is an important part of the official PQ188 package and is required for independent measurement verification.
The PQ188 kit supports two separate measurement-control processes.
The TA347 SOLT calibration kit is used to establish the VNA error correction at the measurement reference planes.
The TA431 check standard is then measured after calibration to verify that the complete measurement setup produces results consistent with its traceable reference data.
This combination can help identify:
A calibration kit corrects systematic errors. A check standard provides an independent test of the corrected setup.
The PQ188 kit uses premium PC3.5 interfaces in its test leads and SOLT calibration standards.
PC3.5 connectors are mechanically compatible with correctly specified SMA interfaces but are manufactured to tighter tolerances for improved measurement repeatability.
The premium interface is suitable for:
The TA347 calibration kit provides female PC3.5 calibration reference planes, while the TA338 test leads terminate in PC3.5 male connectors at the measurement end.
The package includes two TA338 premium 8.5 GHz flex-form test leads.
Each test lead provides:
The flex-form construction allows the cable to remain in a selected position until intentionally moved. This helps improve repeatability during fixed bench measurements and calibration workflows.
Cable movement after calibration can change insertion phase and amplitude, creating measurement error.
Pico states that its premium TA338 and TA339 PC3.5 test leads produce approximately 1.1° phase change at 8.5 GHz under its defined flexing test. Standard SMA leads show a larger phase change under the same test.
Improved phase stability is valuable for:
The cables should still be positioned before calibration and moved as little as possible during measurement.
The PQ188 includes the TA347 Premium 8.5 GHz SOLT Calibration Kit with PC3.5 female interfaces.
The TA347 is a manual mechanical calibration kit containing:
The TA347 is characterised from 300 kHz to 8.5 GHz and is intended for accurate two-port VNA calibration.
The TA347 is not:
Each mechanical standard must be connected manually when requested by the VNA calibration workflow.
SOLT represents:
These standards allow the VNA to calculate corrections for systematic errors such as:
The characterisation data supplied with the TA347 represents the actual behaviour of the standards rather than assuming they are electrically ideal.
The PQ188 includes the TA431 CHK-NON-F non-insertable SMA female-to-female check standard.
The TA431 consists of:
Its smooth, predictable mismatch presents a more demanding verification than a simple through connection.
A highly matched through connection may not expose all errors in a calibrated VNA setup.
The TA431 introduces a known mismatch and transmission response that varies across frequency. Comparing the measured response with its traceable Touchstone data helps evaluate the system under more realistic and demanding conditions.
It supports verification of:
The TA431 supports non-insertable, known-through and unknown-through calibration configurations.
The TA347 calibration kit and TA431 check standard are supplied with reference data traceable to national standards.
The data is linked to the individual standard or kit and accounts for frequency-dependent behaviour such as:
Traceable data supports:
The RevineTech page should not automatically claim that a specific NABL certificate is included unless its scope, certificate number and applicability to the supplied components are confirmed separately.
The PQ188 kit is intended to help realise and verify the professional measurement capability of:
The kit’s components are characterised to 8.5 GHz, covering the full frequency range of both current PicoVNA models.
The TA338 test leads connect from the Type N PicoVNA ports to PC3.5 male measurement interfaces. The TA347 female SOLT standards mate directly with the PC3.5 male lead ends.
The TA431 check standard uses SMA female interfaces that are mechanically compatible with the PC3.5 male test leads when handled correctly.
The kit is designed around PicoVNA systems, but its characterised mechanical standards and industry-standard reference data may also support compatible third-party VNA workflows.
Compatibility depends on:
The TA431 Touchstone data can be used to validate compatible VNAs from other manufacturers.
The PQ188 is particularly suitable for teaching network measurement principles.
Training exercises can demonstrate:
The official Network Metrology Training Kit User’s Guide and associated files support structured classroom and laboratory activities.
Pico identifies the premium demonstrator kit as suitable not only for teaching but also for wider research and doctorate-level projects.
Accurate calibration and independent verification help researchers establish known measurement error terms before testing:
This helps distinguish actual device behaviour from errors introduced by the measurement system.
A normal measurement procedure may include:
The premium components require careful handling.
Recommended practices include:
Poor connector handling can reduce measurement repeatability even when premium standards and traceable data are used.
The PQ188 Network Metrology Premium Demonstrator Kit is suitable for:
RevineTech supplies Pico Technology vector network analysers, premium calibration standards, phase-stable RF cables and check standards.
Technical support can include:
Includes:
The TA347 includes:
The TA431 provides:
Calibration and check-standard data support traceable RF measurement and verification workflows.
Suitable for demonstrating:
| Specification | Details |
|---|---|
| Product name | Network Metrology Premium PC3.5(f) Demonstrator Kit and Carry Case |
| Pico product code | PQ188 |
| Product type | Premium VNA calibration, verification and training kit |
| Maximum component bandwidth | Up to 8.5 GHz |
| Nominal system impedance | 50 Ω |
| Calibration method | Manual two-port SOLT |
| Calibration-kit connector | PC3.5 female |
| Test-lead measurement connector | PC3.5 male |
| VNA-side test-lead connector | Type N male |
| Check-standard connectors | SMA female to SMA female |
| Check-standard type | Non-insertable mismatched transmission line |
| Traceable data | Included |
| Carry case | Included |
| PicoVNA instrument | Not included |
| Component | Quantity | Description |
|---|---|---|
| TA338 premium test lead | 2 | Type N male to PC3.5 male, 8.5 GHz |
| TA347 premium SOLT kit | 1 | PC3.5 female short, open, load and through |
| TA431 check standard | 1 | SMA female-to-female non-insertable standard |
| Calibration data | Included | Serial-number-specific TA347 data |
| Check-standard data | Included | Traceable Touchstone reference data |
| Carry case | 1 | Protective storage and transport case |
| Training documentation | Available | Network Metrology Training Kit User’s Guide and files |
| Specification | Details |
|---|---|
| Product code | TA338 |
| Product type | Premium flex-form VNA test lead |
| VNA connector | Type N male |
| Measurement connector | PC3.5 male |
| Nominal impedance | 50 Ω |
| Maximum specified frequency | 8.5 GHz |
| Connector material | Stainless steel |
| Cable type | Phase-stable flex-form |
| Typical phase variation under Pico flex test | Approximately 1.1° at 8.5 GHz |
| Specification | Details |
|---|---|
| Product code | TA347 |
| Product type | Premium manual mechanical SOLT kit |
| Connector type | PC3.5 female |
| Nominal impedance | 50 Ω |
| Frequency range | 300 kHz to 8.5 GHz |
| Standards | Short, open, load and through |
| Construction | Four-piece, five-port |
| Characterisation | Serial-number-specific traceable data |
| Electronic switching | No |
| USB control | No |
| Internal oven | No |
| Specification | Details |
|---|---|
| Product code | TA431 |
| Product type | Non-insertable VNA check standard |
| Connector configuration | SMA female to SMA female |
| Nominal line impedance | 25 Ω |
| Mismatched-line length | 75 mm |
| Frequency range | 300 kHz to 8.5 GHz |
| Supported measurements | S11, S21, S12 and S22 |
| Reference-data format | Touchstone |
| Traceability | Through PC3.5 standards to national standards |
| Primary purpose | Verification of VNA calibration and measurement setup |