Precision You Can Trust
NABL-Accredited Calibration | Available on Request
The RIGOL MHO934 is a compact 350 MHz high-resolution mixed-signal oscilloscope designed for embedded development, power electronics, automotive testing and circuit debugging. It combines four analogue channels, 12-bit vertical resolution, up to 4 GSa/s sampling, 100 Mpts standard memory, optional memory up to 500 Mpts and 16 digital channels with the PLA2216 logic probe in a portable 7-inch touchscreen platform..
The RIGOL MHO934 Mixed-Signal Oscilloscope is the 350 MHz model in the MHO900 Series. It is designed for engineers, technicians, research laboratories, educational institutions and electronics manufacturers that require accurate analogue acquisition together with digital logic and serial bus analysis.
Built around a 12-bit acquisition system, the MHO934 provides 4,096 vertical quantisation levels. This gives it 16 times more amplitude levels than a conventional 8-bit oscilloscope, helping users observe low-amplitude variations, power-rail ripple, noise, overshoot and fine waveform structures more clearly.
The MHO934 combines:
Its compact enclosure makes it suitable for space-limited engineering benches, educational laboratories, production stations and portable testing.
The MHO934 provides 350 MHz analogue bandwidth across all four analogue input channels.
Unlike the higher-bandwidth MHO954 and MHO984 models, the MHO934 maintains its rated 350 MHz bandwidth when three or four analogue channels are active.
The 350 MHz bandwidth supports applications such as:
The calculated rise time for a 350 MHz oscilloscope is approximately 1 ns, based on the conventional 0.35/bandwidth relationship.
The four analogue channels allow engineers to acquire and compare several related signals on a common time base.
Typical four-channel measurements include:
The MHO934 supports both 1 MΩ and 50 Ω input impedance. This allows it to work with conventional passive probes, active probes and direct 50 Ω signal connections.
The MHO934 uses a 12-bit analogue-to-digital converter that provides 4,096 amplitude levels.
The higher vertical resolution improves waveform visibility when measuring:
Compared with an 8-bit oscilloscope, the MHO934 provides finer voltage quantisation and makes closely spaced signal amplitudes easier to distinguish.
The oscilloscope supports High Resolution processing up to 16 bits.
High Resolution mode can reduce visible random noise and improve low-frequency waveform clarity through digital processing.
It is useful for:
Available bandwidth and sample-rate performance may decrease as higher-resolution modes are selected.
The MHO934 provides a maximum real-time sample rate of up to 4 GSa/s.
The available sample rate depends on the number of enabled analogue channels:
| Active Analogue Channels | Maximum Sample Rate |
|---|---|
| One channel | 4 GSa/s |
| Two channels | 2 GSa/s |
| Three or four channels | 1 GSa/s |
The product should therefore be described as providing up to 4 GSa/s, rather than 4 GSa/s simultaneously across all four analogue channels.
High-speed sampling helps preserve signal detail when analysing:
The MHO934 includes up to 100 Mpts standard acquisition memory. An optional memory upgrade expands the maximum depth to 500 Mpts.
Memory is allocated according to the number of enabled analogue channels:
| Active Analogue Channels | Standard Memory | Optional Maximum Memory |
|---|---|---|
| One channel | 100 Mpts | 500 Mpts |
| Two channels | 50 Mpts | 250 Mpts |
| Three or four channels | 25 Mpts | 125 Mpts |
Deep acquisition memory allows engineers to capture longer signal records while retaining enough sample detail for waveform expansion and analysis.
Typical applications include:
The product page should state 100 Mpts standard and up to 500 Mpts optional, while explaining that memory depth is shared according to the active-channel configuration.
The MHO934 provides:
The maximum capture rate applies under specified single-channel and short-memory acquisition conditions.
Fast waveform capture reduces acquisition dead time and improves the probability of detecting uncommon signal events such as:
The digital phosphor display uses 256-level intensity grading to distinguish frequently occurring waveform activity from rare events.
The MHO934 supports hardware waveform recording and playback of up to 500,000 frames.
Recorded acquisitions can be reviewed frame by frame or played as a continuous sequence.
Waveform recording helps users:
Peak Detect acquisition can capture narrow glitches under supported measurement conditions.
The MHO934 supports 16 digital channels when used with the optional RIGOL PLA2216 logic analyser probe.
The digital channels can be displayed on the same time base as the four analogue channels, allowing users to correlate electrical waveform behaviour with digital logic activity.
Mixed-signal testing is useful for:
The oscilloscope contains the mixed-signal capability, but the PLA2216 logic probe must be ordered separately.
The MHO934 includes standard triggering and decoding for:
Up to four protocol decoders can be displayed simultaneously.
Serial bus analysis displays decoded data together with the underlying electrical waveform. This helps engineers identify:
Protocol sources can be selected from analogue channels or digital channels when the PLA2216 probe is connected.
Additional protocol-analysis options are available for:
These options extend the MHO934 for specialised automotive, audio and aerospace applications.
| Optional Protocol | Typical Application |
|---|---|
| CAN FD | Automotive ECUs and modern vehicle networks |
| FlexRay | Deterministic automotive communication |
| I²S | Digital audio interface testing |
| MIL-STD-1553B | Aerospace and defence bus analysis |
Optional protocol licences should be selected according to the interfaces used in the device under test.
The MHO934 provides multiple trigger types for isolating specific waveform conditions.
Available trigger functions include:
Advanced trigger modes help engineers capture the fault of interest instead of manually reviewing large numbers of normal acquisitions.
Search and navigation tools help users locate events inside long memory records.
Search conditions can include:
Matching results are marked within the acquisition record, allowing users to move directly between abnormal events.
The MHO934 provides a broad range of automatic measurement and waveform-analysis functions.
Available capabilities include:
These tools support general circuit debugging, repetitive verification and production testing.
The MHO934 supports two optional integrated function and arbitrary waveform generator configurations:
Both options provide:
Maximum output frequency depends on the selected waveform type.
The integrated generator can be used for:
RIGOL’s user guide confirms that the MHO934 supports the optional dual-channel 50 MHz and 100 MHz generator functions.
With an optional AFG installed, the MHO934 supports Bode plot analysis.
The Bode plot function can measure:
The supported Bode sweep extends from 10 Hz to a maximum stop frequency of 30 MHz.
Power-supply loop testing may require suitable probes, cables and an injection transformer.
Vertical sensitivity depends on the selected input impedance:
| Input Impedance | Vertical Sensitivity |
|---|---|
| 50 Ω | 200 μV/div to 1 V/div |
| 1 MΩ | 1 mV/div to 10 V/div |
The 200 μV/div setting supports low-level measurements such as:
Probe attenuation, grounding, input loading, bandwidth limitation and environmental interference should be considered when measuring very small signals.
The MHO934 includes a 7-inch capacitive multi-touch display with:
The compact screen and enclosure make the instrument suitable for crowded workbenches and portable engineering applications.
Standard connectivity includes:
These interfaces support:
Wireless accessory compatibility and regional availability should be confirmed before ordering.
The RIGOL MHO934 is suitable for:
Revine Tech supplies RIGOL oscilloscopes, logic probes, protocol-analysis options, waveform-generator upgrades and measurement accessories for professional electronics testing.
Technical selection support can include:
The MHO934 maintains its rated 350 MHz analogue bandwidth when all four channels are enabled.
Four time-correlated inputs allow engineers to compare several signals in embedded, power and control systems.
The 12-bit converter provides 4,096 amplitude levels for improved observation of small waveform variations.
High Resolution processing helps reduce visible noise and improve precision during lower-frequency measurements.
The oscilloscope reaches 4 GSa/s in single-channel operation.
The standard configuration provides up to 100 Mpts for long single-channel acquisitions.
The memory upgrade expands maximum single-channel acquisition depth to 500 Mpts.
Fast recording mode improves the probability of capturing rare waveform abnormalities.
The optional PLA2216 logic probe enables digital and analogue signal correlation.
Parallel, RS232/UART, I²C, SPI, LIN and CAN analysis are included.
CAN FD, FlexRay, I²S and MIL-STD-1553B can be added through software options.
A dual-channel 16-bit waveform generator can be added for circuit stimulation and response testing.
Frequency-response, gain and phase analysis are available with an installed AFG option.
The 50 Ω input path supports small-signal measurements down to 200 μV/div.
The 1024 × 600 capacitive touchscreen provides intuitive operation in a compact enclosure.
Browser-based remote operation supports automated laboratories and remote troubleshooting.
| Specification | RIGOL MHO934 |
|---|---|
| Product Series | RIGOL MHO900 Series |
| Product Type | High-resolution mixed-signal digital oscilloscope |
| Analogue Bandwidth | 350 MHz |
| Analogue Channels | 4 |
| Digital Channels | 16 with optional PLA2216 probe |
| Hardware Vertical Resolution | 12 bits |
| High Resolution Mode | Up to 16 bits |
| Maximum Real-Time Sample Rate | Up to 4 GSa/s |
| Standard Maximum Memory | 100 Mpts |
| Optional Maximum Memory | 500 Mpts |
| Vector Capture Rate | Up to 30,000 wfms/s |
| Fast Recording Rate | Up to 1,000,000 wfms/s |
| Waveform Recording | Up to 500,000 frames |
| Display | 7-inch capacitive multi-touch |
| Display Resolution | 1024 × 600 |
| Intensity Grading | 256 levels |
| Input Impedance | 1 MΩ ±1% or 50 Ω ±1% |
| Waveform Generator | Optional dual-channel 50 MHz or 100 MHz |
| Bode Plot | Supported with optional AFG |
| Connectivity | USB Host, USB Device, 100 Mbps LAN and HDMI |
| Remote Control | Web Control and SCPI |
| Active Analogue Channels | Maximum Bandwidth |
|---|---|
| One channel | 350 MHz |
| Two channels | 350 MHz |
| Three or four channels | 350 MHz |
| Active Analogue Channels | Maximum Sample Rate |
|---|---|
| One channel | 4 GSa/s |
| Two channels | 2 GSa/s |
| Three or four channels | 1 GSa/s |
| Active Analogue Channels | Standard Memory | Optional Memory |
|---|---|---|
| One channel | 100 Mpts | 500 Mpts |
| Two channels | 50 Mpts | 250 Mpts |
| Three or four channels | 25 Mpts | 125 Mpts |
| Specification | Details |
|---|---|
| Sensitivity at 50 Ω | 200 μV/div to 1 V/div |
| Sensitivity at 1 MΩ | 1 mV/div to 10 V/div |
| Input Coupling | DC, AC or GND |
| Input Impedance | 1 MΩ ±1% or 50 Ω ±1% |
| Input Capacitance at 1 MΩ | Approximately 18 pF |
| Maximum Input at 1 MΩ | CAT I 300 Vrms, 400 V peak |
| Maximum Input at 50 Ω | 5 Vrms |
| Calculated Rise Time | Approximately 1 ns |
| Protocol | Availability |
|---|---|
| Parallel | Standard |
| RS232/UART | Standard |
| I²C | Standard |
| SPI | Standard |
| LIN | Standard |
| CAN | Standard |
| Protocol | Option Category |
|---|---|
| CAN FD | Automotive analysis |
| FlexRay | FlexRay analysis |
| I²S | Audio analysis |
| MIL-STD-1553B | Aerospace analysis |
| Specification | Details |
|---|---|
| Generator Channels | 2 |
| Available Configurations | AFG50 or AFG100 |
| Maximum Sine Frequency | 50 MHz or 100 MHz |
| Sampling Rate | 1 GSa/s |
| Vertical Resolution | 16 bits |
| Arbitrary Waveform Length | 16 kpts |
| User-Defined Waveforms | Supported |
| Bode Plot Sweep | 10 Hz to 30 MHz |
| Model | Maximum Bandwidth | Analogue Channels | Maximum Sample Rate | Standard Memory | Optional Memory |
|---|---|---|---|---|---|
| MHO934 | 350 MHz | 4 | Up to 4 GSa/s | 100 Mpts | 500 Mpts |
| MHO954 | 500 MHz | 4 | Up to 4 GSa/s | 100 Mpts | 500 Mpts |
| MHO984 | 800 MHz | 4 | Up to 4 GSa/s | 100 Mpts | 500 Mpts |